- Contact Person : Ms. Gui Teresa
- Company Name : Harbin East Alarm Equipment Development Co., Ltd.
- Tel : 86-451-82380878
- Fax : 86-451-82380879
- Address : Heilongjiang,Harbin,No.119, Fushui Road, Nangang District
- Country/Region : China
- Zip : 150090
Fixed explosion-proof multi gas analyzer for hazardous warning
Fixed explosion-proof multi gas analyzer for hazardous warning GQB-200A10
Performance and characteristics
1 test two different gases simultaneously
2 in the same domestic industry have no this technology application
3 4-20mA, Rs485 main line system (optional)
4 120dB explosion-proof sound-light alarm
5 high brightness LED can be instructed in ten metres away
6 the original imported sensor
7 stainless steel shell
Rs485 and 4-20mA double output can access any field devices Calibrating wihtout open cover and makes operation more convenient.
Certificates
1.one patent of practical new technique.
2.two patents of appearance technique.
3.fire control type approval of the ministry of public security.
4.National explosion-proof electric inspection.
Characteristic of sensor
1.plug and play any time
2. High concentrations protection (applies only to catalytic sensor)
3. High precision & wide range hardware VGA (variable gain amplifier) avoids the sensitivity decrease brought only by software amplification.
4. Each probe contains a extra temperature sensor to compensate the impacts to gas sensor by temperature.
5. Artificial intelligence compensation technology makes reading more smooth and stable.
6. Sensor lifetime system from the viewpoint of sensor helps the user know whether the sensor need to replace or not.
7. Double output of current completely satisfy the requirements of Dual-use machine.
The compound gas transmitter of GQB-200A10 is applied for semiconductor, catalytic combustion, electrochemistry, nondispersive infrared and PID sensors and can be used between any two kinds of the above sensors. It’s the first choice of exceeding the imported products and complex gas ambients.
Attention: GQB-200G10 cannot be applied for two catalytic combustion sensors working at the same time.
Technical parameters
Type of sensor | Catalytic combustion sensor | seiicIonductor sensor | Electrochemical sensor | PID sensor | IR sensor | ||||
Operating current | <400mA | ||||||||
Working voltage | DC24V±5V | ||||||||
Signal outputs | 4-20mA, RS-485(optional) | ||||||||
display | 3+2 LED display 3-color LED lights | ||||||||
Relay output | AC220V/5A or DC24V/5A | ||||||||
Detection gas | Combustible gas | Combustible and toxic gas | Toxic gas | TVOC | Combustible gas CO2 | ||||
Detection range | 0-100%LEL | 0-100%LEL 0-100ppm | 0-100ppm 0-30%vol | 0-100ppm | 0-100%LEL | ||||
Alarm concentration | adjustable | ||||||||
T90 | <15s | <15s | <30s | <10s | <30s | ||||
Detection precision | 3% | 1% | 1% | 1% | 3% | ||||
Zero drift | 2%/year | ||||||||
Lifetime of detector | >3year | >3year | >2year | >1year | >5year | ||||
Allowable application areas | Hazardous location zone I&II | ||||||||
Alarm of sound & light | 120dB red color alarm | ||||||||
Ambient condition | Outdoor usage | ||||||||
Relative humidity | 10~95%RH(No condensation) | ||||||||
Atm press | 86~106Kpa | ||||||||
Operation temperature | -40ºC~+70ºC | -40ºC~+70ºC | -20ºC~+50ºC | 20ºC~+50ºC | -40ºC~+70ºC | ||||
Storage temperature | -40ºC~+85ºC | -40ºC~+85ºC | -25ºC~+50ºC | -25ºC~+50ºC | -40ºC~+85ºC | ||||
Transmission cable | Three-core shielding line for 4-20mA; four-core shielding line for RS485 Wire diamete 1~1. 5 mm2 | ||||||||
Transmission range | 4-20mA≤2Km; RS485≤1.2Km | ||||||||
Electric connector | M20*1.5(cast aluminium); | ||||||||
Explosion-proof grade | ExdIICT6 | ||||||||
weight | 2.5kg (cast aluminium); | ||||||||
Protection grade | IP65 standard (IP66,IP67 optional) | ||||||||
Fixed explosion-proof multi gas analyzer for hazardous warning