Harbin East Alarm Equipment Development Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Gui Teresa
  • Company Name : Harbin East Alarm Equipment Development Co., Ltd.
  • Tel : 86-451-82380878
  • Fax : 86-451-82380879
  • Address : Heilongjiang,Harbin,No.119, Fushui Road, Nangang District
  • Country/Region : China
  • Zip : 150090

Explosion-proof combustible and toxic gas analyzer for complex detection system

Explosion-proof combustible and toxic gas analyzer for complex detection system
Product Detailed
Related Categories:Gas Analyzers
gas analyzer Appling for pipage detection Continuous sucking leak gas in hot,humid temp, high pressure highland complex areas.

Explosion-proof combustible and toxic gas analyzer for complex detection system   E-6000/D 

E-6000/D series gas analyzer system is the new launched & the enrichment version of E-6000/D, It is the effective extending of diffusion gas detection area which applies the combination of gas detector and gas sampling analyze technique. It can widely use for the continuous gas detection for the aimed environments.

E-6000/D series gas analyzer system can detect the regions for aimed tank, pipeline or in the pit where is inconvenient detection and installation for the traditional gas detectors.

The principle is extracting the aimed gas and sending it back to the detector by this analyzer system to reach the purpose of detecting the aim gas concentration. It can also detect the anaerobic or anoxia tank and stack for mixture gas analyzer.

It applies the modularization design and save the application space and easy to maintain and calibrate and debug and by the Micro pump of high-performance automatic suction with the functions of long services lifetime, wide detection range and strong adaptability.

A newest launched gas analyzer, a effective extension for the diffusing gas detection, apply analyzer technque of gas sampling, a analyzer used for gas concentration of target ambient, detecting the gas for canning, pipeline and down hole conditions that the fixed gas detector doesn’t work or can’t installment.

Its working pronciple is that the gas analyzer extracts the gas of target areas and send back to analyzer, and achieve the aim of detecting the target gas concentration.

Characteristics

-Automatic suction type of gas analyzer with the high reliable & high performance automatic suction type of micro pump.

-Explosion-proof design for structure and can suck continuously the combustible & toxic gases.

-Built-in high performance suction type of micro pump can use for environments of moist, high altitude emission, and ordinary pressure tube to continuously suck in gas leakage for gas detection.

-Stable working performance, long service lifetime, high sensitivity, good selectiveness etc.

-4-20ma standard output signal with max transmission distance of 2km.

-Spot setting available and can realize calibration & maintenance by single person.

-Detection for 70 kinds of combustible, oxygen & toxic gases.

-LED display for current time concentration detection.

-The volume of sucked gas is adjustable

Technical parameters

Signal output

4-20mA; RS485

sensitibity drift

less than2%FC/month

Working voltage

AC220V 50HZ

display

3+2 LED/ 3-color indication

power dissipation

 less than5W (non heat accompany)

transmission cable

4-core water-proof  screening cable

Alarm setting

7% vol (O2); 10ppm( H2S)

Max output distance

no more than 2km

Relay output

5A@220V/ 5A@24V DC

Explosion-proof grade

ExdIICT6

Detection gases

O2 or H2S

Weight

80kg

Detection range

0-30%vol, 0-100ppm

Heat accompany working woltage

AC220V 50HZ

Sensor type

Electrochemistry sensor

Heat accompany power dissipation

 less than 200W

Lifetime of analyzer

more than 2 years

Sampling connecting

DN10 flg

lifetime of air pump

more than 2 years

Sampling pipeline

Diameter 6 stainless steel

Lifetime of sensor

more than1 year

Operation press

entrance :0.1-0.4Mpa  airvent:+/-7kpa

Applying location

Zone I of hazardous location

Size of analyzer

900X1100X220

Outdoor usage

respond time

T90 NO MORE THAN 30s ( increasing 5M of sampling tube, the T90 added 20s)

Zero drift

less than 2%FC/month

Detection precision

+/-1%

Ambient condicion

Temperature (-40~+70)°C

RH:(10~95)%RH

Atmosphere press(86~106)kpa

Explosion-proof combustible and toxic gas analyzer for complex detection system



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.