- Contact Person : Ms. Gui Teresa
- Company Name : Harbin East Alarm Equipment Development Co., Ltd.
- Tel : 86-451-82380878
- Fax : 86-451-82380879
- Address : Heilongjiang,Harbin,No.119, Fushui Road, Nangang District
- Country/Region : China
- Zip : 150090
Online explosion-proof audible and visual gas cylinder leak detector for combustible and toxic gas detection
Online Industrial explosion-proof audible and visual gas cylinder leak detector for combustible and toxic gas detection GQB-200G9
Performance and characteristics
1. full function of gas detection
2. Sensor lifetime readable
3. Multi-sensor design, applied for extreme environments
4. Importing sensor with original package
5. Double-window LED display with 3+2 digits
6. High brightness LED instruction( clearly seen in 10 meters)
7. Output of 4-20mA,Rs485( optional)
8. All stainless steel, 120dB sound with explosion-proof sound&light alarm
Certificates
1.one patent of practical new technique.
2.two patents of appearance technique.
3.fire control type approval of the ministry of public security.
4.National explosion-proof electric inspection.
Characteristics of sensor
1.plug and play
2. High concentrations protection (applies only to catalytic sensor)
3. High precision & wide range hardware VGA (variable gain amplifier) avoids the sensitivity decrease brought only by software amplification.
4. Each probe contains a extra temperature sensor to compensate the impacts to gas sensor by temperature.
5. Artificial intelligence compensation technology makes reading more smooth and stable.
6. Sensor lifetime system from the viewpoint of sensor helps the user know whether the sensor need to replace or not.
7. Double output of current completely satisfy the requirements of Dual-use machine.
Technical parameters
Sensor type | Catalysis sensor |
Operating current | <400mA |
Operating voltage | DC24V±5V |
Signal outputs | 4-20mA,RS-485(optional) |
display | 3+2 LED display 3-color LED status light |
Relay output | AC220V/3A DC24V/3A |
Detection gas | Combustible gas |
Detection range | 0-100%LEL |
Alarm concentration | adjustable |
T90 | <15s |
Detection precision | 3% |
Zero drift | 2%/year |
Lifetime of detector | >3year |
Allowable application areas | Hazardous location zone I & II |
Alarm of sound & light | 120dB red color alarm |
Ambient condition | Outdoor usage |
Relative humidity | 10~95%RH(Non condensation) |
Atm press | 86~106Kpa |
Operation temperature | -40ºC~+70ºC |
Storage temperature | -40ºC~+85ºC |
Transmission cable | Three-core shielding line; Wire diamete 1~1. 5 mm2 |
Transmission range | ≤2Km(4-20mA); ≤1.2Km(RS485); |
Electric connector | G3/4(stainless steel) |
Explosion-proof grade | ExdIICT6 |
weight | 4kg(stainless steel) |
Protection grade | IP65/IP66/IP67 |
Standard configuration
FSG-103 explosion-proof audible & visual alarm; Signal adjustor (one for five pieces), installation support; sun visor; environmental protection; user manual; gland nut; certificate of quality.
Selective configuration
Calibrating gas; flow meter; reducing valve; breather pipe.
Online explosion-proof audible and visual gas cylinder leak detector for combustible and toxic gas detection